Resumen:
Manganese is the Earth’s crust’s third most abundant transition metal. Decades of increased mining activities worldwide have inevitably led to the release of large amounts of this metal into the environment, specifically in water resources. Up to a certain level, manganese acts as an essential micronutrient to maintain health and support the growth and development of microorganisms, plants, and animals, while above a specific limit, manganese can cause toxicity in aquatic and terrestrial ecosystems. There are conventional ways to remove manganese from water, such as chemical precipitation, sorption, and biological methods. However, other treatments have yet to be studied
much, such as reverse osmosis (RO), which has demonstrated its effectiveness in the removal of heavy metals and could be a suitable alternative for manganese removal if its energy consumption is reduced. This research presents mathematical and statistical modeling of the behavior of a system in laboratory-scale RO. The principal finding was that it is possible to remove Mn using the RO operated with low pressures without decreasing the sustainable removal efficiency. Reducing the operating costs of RO opens the possibility of implementing RO in different contexts where there are problems with water contamination and economic limitations.